Minimize errors and enhance quality.

The new ACL TOP Family 50 Series* offers the most advanced automation and quality management for routine-to-specialty Hemostasis testing. Engineered to minimize errors and enhance quality, all models are standardized and offer automated pre-analytical sample integrity checks. Plus, all ACL TOP 50 Series systems are optimized for a comprehensive panel of HemosIL assays to offer a complete disease-state management solution.  


Features include: 

  • Pre-analytical integrity checks to detect under-filled sample tubes, abnormal sample aspiration, and interference from Hemolysis, Bilirubin or Lipemia 
  • New lab accreditation tools document compliance to quality standards 
  • Enhanced system security from comprehensive audit trail, no-click audit reports with e-signature, second-level password, automatic system log-off and user specific log-in


All ACL TOP systems offer true standardization for superior performance:

  • Same quality results
  • Same comprehensive reagent portfolio
  • Same features and usability
  • Same powerful and intuitive software

And now, ACL TOP Family 50 Series systems provide:

  • Same assay-specific pre-analytical sample checks
  • Same advanced lab accreditation support
  • Same advanced quality management

 

 


ACL TOP
750

ACL TOP
750 CTS

ACL TOP
550 CTS

ACL TOP
350 CTS

Throughput
(PT/hr)

up to 360

up to 270

up to 240

up to 110

Samples
onboard

120

120

80

40

Reagents
onboard

60

60

40

26

 

 



General Screening and Anticoagulant Monitoring/Measurement

PTInsert Sheet MSDS
0020002950
RecombiPlasTin 2G 8mL
0020003050
RecombiPlasTin 2G 20mL
0008469810
PT-Fibrinogen HS Plus
APTTInsert Sheet MSDS
0020006300
APTT-SP
0020006800
SynthASil
Calcium ChloridesInsert Sheet MSDS
FibrinogenInsert Sheet MSDS
0020301100
Fibrinogen-C
0020301800
Q.F.A. Thrombin 2ml
Thrombin TimeInsert Sheet MSDS
HeparinInsert Sheet MSDS
0020302600
Liquid Anti-Xa
Dabigatran*Insert Sheet MSDS
0020302800
Direct Thrombin Inhibitor Assay*
Rivaroxaban*Insert Sheet MSDS
Apixaban*Insert Sheet MSDS
Local ISI Assignment and ValidationInsert Sheet MSDS
*Pending 510(k)-clearance. Not currently saleable in N. America.

D-Dimer

D-Dimer (FEU)Insert Sheet MSDS
0020500100
D-Dimer HS 500
AcuStar D-Dimer (FEU)Insert Sheet MSDS
D-Dimer (D-DU)Insert Sheet MSDS
0020007700
D-Dimer HS
0020008500
D-Dimer
D-Dimer ControlsInsert Sheet MSDS
D-Dimer ManualInsert Sheet MSDS
FDPInsert Sheet MSDS
FDP CalibratorsInsert Sheet MSDS
FDP ControlsInsert Sheet MSDS
*Pending 510(k)-clearance. Not currently saleable in N. America.
**Chemiluminescent technology assay. For use on ACL AcuStar Hemostasis Testing System.

Heparin-Induced Thrombocytopenia

HIT-Ab(PF4-H)Insert Sheet MSDS
0020301200
HIT-Ab(PF4-H)
AcuStar HITInsert Sheet MSDS
* Pending 510(k)-clearance. Not currently saleable in N. America.
** Chemiluminescent technology assay. For use on ACL AcuStar Hemostasis Testing System.

Thrombophilia

AntithrombinInsert Sheet MSDS
0020008900
Antithrombin
Protein CInsert Sheet MSDS
0020300500
Protein C
Protein SInsert Sheet MSDS
0020002700
Free Protein S
APC-RInsert Sheet MSDS
0020008700
Factor V Leiden
HomocysteineInsert Sheet MSDS
0020007800
Homocysteine
Molecular TechnologyInsert Sheet MSDS
* Pending 510(k)-clearance. Not currently saleable in N. America.

Antiphospholipid Syndrome

Lupus AnticoagulantsInsert Sheet MSDS
0020301500
dRVVT Screen
0020301600
dRVVT Confirm
0020004800
Silica Clotting Time
AcuStar AntiphospholipidInsert Sheet MSDS
*Pending 510(k)-clearance. Not currently saleable in N. America.
**Chemiluminescent technology assay. For use on ACL AcuStar Hemostasis Testing System.

von Willebrand Disease (VWD)

VWF AntigenInsert Sheet MSDS
0020002300
von Willebrand Factor Antigen
VWF ActivityInsert Sheet MSDS
0020004700
von Willebrand Factor Activity
VWF Ristocetin Cofactor Activity*Insert Sheet MSDS
AcuStar VWFInsert Sheet MSDS
*Pending 510(k)-clearance. Not currently saleable in N. America.
**Chemiluminescent technology assay. For use on ACL AcuStar Hemostasis Testing System.

Fibrinolysis

PlasminogenInsert Sheet MSDS
0020009000
Plasminogen
Plasmin InhibitorInsert Sheet MSDS
0020009200
Plasmin Inhibitor

New ACL TOP Family 50 Series—extending standardization beyond the analytical phase.


* Not available in all countries

Werfen International



- Autoimmunity
- Clinical Chemistry
- Critical Care Diagnostics
- Hemostasis Diagnostics
- Serology
Werfen
Products
Country Contacts
News & Events
Contact us
Work with us

© Copyright 2014
All rights reserved.

Privacy Policy

Werfen.com